No data

No data

Products


Contact Information


Company address: 146B-101 Chunfeng Road, Longbeiling, Tangxia Town, Dongguan City

Mobile/WeChat:13713053585

Enterprise E-mail:2649073675@qq.com

undefined
+
  • undefined
WMZ12D 15V/18V overcurrent protection PTC thermistor

Huaju Electronics overcurrent protection PTC thermistor is mainly used for overcurrent and overheating protection of [transformer (adapter)/primary coil/charger/digital multimeter/smart meter/micromotor/transistor], etc., and is directly connected in series with the load In the circuit, when an abnormal condition occurs on the line, it can automatically limit the overcurrent or block the current. When the fault is eliminated, it will return to its original state. It is commonly known as the "10,000-time fuse".

Classification:

Overcurrent protection PTC thermistor

Service Support:

137 1305 3585

  • 产品描述
  • 产品规格及参数
  •   Hua Ju Electronics is a professional PTC thermistor manufacturer. The over-current protection PTC produced by Hua Ju Electronics is widely used in various electronic products. The PTC thermistor for over-current protection is an automatic protection against abnormal temperature and abnormal current. The restored protective element is commonly known as "resettable fuse" and "ten thousand times fuse". It replaces traditional fuses and can be widely used for overcurrent and overheating protection of motors, transformers, switching power supplies, electronic circuits, etc. PTC thermistors for overcurrent protection limit consumption in the entire circuit through sudden changes in resistance to reduce residual current values. .Traditional fuses cannot recover by themselves after the line is blown, while PTC thermistors for overcurrent protection can return to the pre-protection state after the fault is removed, and can realize their overcurrent and overheating protection functions when a fault occurs again.

      1. Application scope:

      Huaju Electronics overcurrent protection PTC thermistor is mainly used for overcurrent and overheating protection of [transformer (adapter)/primary coil/charger/digital multimeter/smart meter/micromotor/transistor], etc., and is directly connected in series with the load In the circuit, when an abnormal condition occurs on the line, it can automatically limit the overcurrent or block the current. When the fault is eliminated, it will return to its original state. It is commonly known as the "10,000-time fuse".

      2. Features:

      ·Contactless circuit and component protection·Automatic overcurrent limitation

      ·Automatic recovery after troubleshooting ·No noise or sparks during operation

      ·Reliable and easy to use

      3. Application principle:

      Connect the overcurrent protection PTC thermistor in series in the power circuit. When the circuit is in a normal state, the current flowing through the PTC is less than the rated current. The PTC is in normal state and has a very small resistance, which will not affect the electronic ballast (energy saving). Normal operation of protected circuits such as lamps, transformers, and multimeters. When the circuit current greatly exceeds the rated current, the PTC suddenly heats up and the resistance suddenly increases to a high resistance state, thereby limiting or blocking the current and protecting the circuit from damage. After the current returns to normal, the PTC also automatically returns to the low resistance state, and the circuit returns to normal operation.

      Overcurrent protection PTC thermistors are used in overcurrent protection application fields such as [transformer (adapter)/primary coil/charger/digital multimeter/smart electricity meter/micromotor/transistor]. Nanjing Huaju relies on its scientific research and technology Taking advantages in other aspects, it was the first to launch the WMZ12A product featuring high withstand voltage (V≥300V AC).

      3. Model name, appearance structure and dimensions:

      

    1

     

      

    1

     

      When using PTC as an overcurrent protection component, you should generally select appropriate specifications for maximum non-operating current and maximum working voltage. Factors such as the component's overall dimensions, rated zero-power resistance, and operating temperature range should also be considered. Usually, 1.2 to 1.5 times the maximum operating current of the circuit during normal operation is taken as the maximum non-operating current of the PTC; the voltage that the line may apply to the PTC under normal or abnormal conditions should not be greater than its maximum operating voltage.

      

    1

     

      .The main technical parameters:

      Mainly used for overcurrent protection of chargers, adapters (primary coils), energy meters, digital multimeters, etc.

    model Rated resistance value No action current Operating current Maximum work Maximum current Curie temperature Dimensions
    R25(Ω) Int(mA) @25℃ Voltage (mm)
    ±25% @25℃ @60℃ It(mA) Vmax(V) Imax(A) Tc(℃) Dmax Tmax Φd
    Withstand voltage 15Vac series
    WMZ12D-10R1R2H15 1.2 850 700 1550 15 4.3 140 11.0 4.0 0.6
    WMZ12D-08R1R0H15 1.0 850 700 1500 15 3.O 9.0 4.0 0.6
    WMZ12D-08R1R8H15 1.8 600 500 1100 15 3.0 9.0 4.0 0.6
    WMZ12D-07R1R0H15 1.0 750 600 1350 15 2.5 8.0 4.0 0.6
    WMZ12D-07R1R2H15 1.2 650 550 1200 15 2.5 8.0 4.0 0.6
    WMZ12D-05R4R6H15 4.6 350 300 680 15 1.0 6.5 4.0 0.6
    WMZ12D-03R13RH15 13 180 150 350 15 0.7 4.5 4.0 0.5
    Withstand voltage 18Vac series
    WMZ12D-10P1R2H18 1.2 700 600 1400 18 4.3 120 11.0 4.0 0.6
    WMZ12D-08P1R018 1.0 650 550 1200 18 3.0 9.0 4.0 0.6
    WMZ12D-08P1R8H18 1.8 550 450 1000 18 3.0 9.0 4.0 0.6
    WMZ12D-05P4R6H18 4.6 300 250 580 18 1.0 6.5 4.0 0.6
    WMZ12D-03P13RRH18 13 145 120 280 18 0.7 4.5 4.0 0.5

Description page content......